Dry Basis to Wet Basis Calculator
Dry Basis to Wet Basis Calculator: Restore Moisture Dilution
When a regulatory limit or reference value is given on a dry basis but you need to know the actual concentration present in the real, moisture-containing flue gas stream, this calculator converts it back to wet basis.
The Formula
Wet% = Dry% × (1 − Moisture Fraction)
Worked Example
A dry-basis reading shows 11.11% for a species, with 10% moisture content in the gas stream.
Wet% = 11.11 × (1 − 0.10) = 10.00%
How to Use This Calculator
- Enter the dry-basis gas concentration percentage.
- Enter the moisture fraction of the gas stream (0-1).
- Click Calculate to get the wet-basis equivalent.
Related Calculations
Use with the Wet Basis to Dry Basis Gas Calculator to convert in the opposite direction.