Burner Warm-Up Time Calculator
Burner Warm-Up Time Calculator
Cold-starting a burner means first heating its own refractory and chamber mass before the system reaches steady operating temperature - this calculator estimates how long that takes.
The Formula
t = (m × c × ΔT) / Q
Worked Example
200 kg of refractory mass, specific heat 1.0 kJ/kgK, needing an 800K temperature rise, with 100 kW of heat input:
Energy required = 200 × 1.0 × 800 = 160,000 kJ
t = 160,000 / 100 = 1,600 seconds = 26.7 minutes
How to Use This Calculator
- Enter the mass being heated (refractory, casing, etc).
- Enter its specific heat capacity.
- Enter the temperature rise needed.
- Enter the heat input rate during warm-up.
Note: this assumes all heat input goes toward warming the mass, ignoring ongoing losses during warm-up - real warm-up typically runs somewhat longer than this simplified estimate.